IBM Books

Event Logging System Messages Guide


Environment Functions (ENV)

This chapter describes Environment Functions (ENV) messages. For information on message content and how to use the message, refer to the Introduction.

ENV.001 

Level: C-TRACE

Short Syntax: ENV.001 current temp temperature_celsiusC ( temperature_fahrenheitF)

Long Syntax: ENV.001 Current ambient temperature: temperature_celsiusC ( temperature_fahrenheitF)

Description: The router generates this message each time it recalculates the current ambient temperature.

ENV.002 

Level: U-TRACE

Short Syntax: ENV.002 hi temp thresh active: threshold_temperature_celsiusC ( threshold_temperature_fahrenheitF)

Long Syntax: ENV.002 High temperature threshold is active. Threshold: threshold_temperature_celsiusC ( threshold_temperature_fahrenheitF)

Description: Trace message indicating that the router passed the high temperature threshold and the high temperature threshold is active. The router generates this message each time it recalculates the current ambient temperature and the current ambient temperature surpasses the high temperature threshold.

ENV.003 

Level: U-TRACE

Short Syntax: ENV.003 low temp thresh active: threshold_temperature_celsiusC ( threshold_temperature_fahrenheitF)

Long Syntax: ENV.003 Low temperature threshold is active. Threshold: threshold_temperature_celsiusC ( threshold_temperature_fahrenheitF)

Description: Trace message indicating that the router passed the low temperature threshold and the low temperature threshold is active. The router generates this message each time it recalculates the current ambient temperature and the current ambient temperature is below the low temperature threshold.

ENV.004 

Level: UE-ERROR

Short Syntax: ENV.004 hi temp thresh exceeded: threshold_temperature_celsiusC ( threshold_temperature_fahrenheitF)

Long Syntax: ENV.004 High temperature threshold has been exceeded. Threshold: threshold_temperature_celsiusC ( threshold_temperature_fahrenheitF)

Description: Trace message indicating that the router passed the high temperature threshold and the high temperature threshold is active. The router generates this message when it first detects that the high temperature condition is active. If the ambient temperature of the router exceeds its stated operational maximum (set at the factory, independent of the configured high temperature threshold), it automatically shuts down until the ambient temperature returns to within its stated operational range. This prevents damage to the router and the data flow.

Cause: The value of the high temperature threshold is configured too low for the site's average operational ambient temperature.

Action: Verify that the high temperature threshold is set to the correct desired temperature, in consideration of the particular site's normal ambient temperature range.

Cause: Possible failure of the router's internal fan.

Action: Verify the operation of the router's internal fan. If the internal fan is not operational, contact customer service.

Cause: Possible failure of the environmental control system of the site where the router resides.

Action: Verify the operation of the site's environmental control system.

ENV.005 

Level: UE-ERROR

Short Syntax: ENV.005 low temp thresh exceeded: threshold_temperature_celsiusC ( threshold_temperature_fahrenheitF)

Long Syntax: ENV.005 Low temperature threshold has been exceeded. Threshold: threshold_temperature_celsiusC ( threshold_temperature_fahrenheitF)

Description: Trace message indicating that the router passed the low temperature threshold and the low temperature threshold is active. The router generates this message when it first detects that the low temperature condition is active.

Cause: The value of the low temperature threshold is configured too high for the site's average operational ambient temperature.

Action: Verify that the low temperature threshold has been set to the correct desired temperature, with consideration of the site's normal ambient temperature range.

Cause: Possible failure of the environmental control system of the site where the router resides.

Action: Verify the operation of the site's environmental control system.


[ Top of Page | Previous Page | Next Page | Table of Contents ]